Apc
APC AP8853 power distribution unit PDU 42 AC outlets 0U Black AP8853
- UPC:
- 0731304277019
- MPN:
- AP8853
- Condition:
- New
- Availability:
- Available with FREE Delivery (usually delivered within 5-7 working days)
Description
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. The output and input connections are (36) C13 & (6) C19, and the cable length is 3m. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Specs
Design
PDU types
A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Metered
Type
Characteristics of the device.
Single-phase
Rack capacity
The spase that device fill in rack.
0U
Mounting
What size the mounting head of the product is, to couple it with a camera.
Vertical
Product colour
The colour e.g. red, blue, green, black, white.
Black
Ports & interfaces
AC outlets quantity
The number of sockets in the device where AC electrical power can be connected.
42 AC outlet(s)
Power plug
A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
IEC309
AC outlet types
The type of outlet for AC electricity.
C13 coupler, C19 coupler
Input connection type
The type of connection /port for the input(s) into this device e.g. USB.
IEC 309 32A 2P+E
Output connections
36x IEC 320 C13 6x IEC 320 C19
Features
Cable length
How long the cable is.
3 m
Management features
Monitoring
Current, Power, Voltage
Power
AC input frequency
50 - 60 Hz
Nominal output voltage
The voltage which the manufacturer states that the device can produce.
230 V
Load capacity
7680 VA
Power
Maximum input current per phase
32 A
Maximum total current draw per phase
32 A
Maximum power
The maximum power that can be put into or produced by the device.
7680 W
Certificates
Certification
RoHS, REACH IEC 60950,VDE
Operational conditions
Operating temperature (T-T)
The minimum and maximum temperatures at which the product can be safely operated.
5 - 45 ?C
Storage temperature (T-T)
The minimum and maximum temperatures at which the product can be safely stored.
-25 - 65 ?C
Operating relative humidity (H-H)
5 - 95%
Storage relative humidity (H-H)
5 - 95%
Weight & dimensions
Width
The measurement or extent of something from side to side.
56 mm
Depth
The distance from the front to the back of something.
44 mm
Height
The measurement of the product from head to foot or from base to top.
91 mm
Weight
Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
6.93 kg
Logistics data
Total carbon footprint (kg of CO2e)
The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
28921.23
View AllClose
Specs
Design
PDU types
A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Metered
Type
Characteristics of the device.
Single-phase
Rack capacity
The spase that device fill in rack.
0U
Mounting
What size the mounting head of the product is, to couple it with a camera.
Vertical
Product colour
The colour e.g. red, blue, green, black, white.
Black
Ports & interfaces
AC outlets quantity
The number of sockets in the device where AC electrical power can be connected.
42 AC outlet(s)
Power plug
A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
IEC309
AC outlet types
The type of outlet for AC electricity.
C13 coupler, C19 coupler
Input connection type
The type of connection /port for the input(s) into this device e.g. USB.
IEC 309 32A 2P+E
Output connections
36x IEC 320 C13 6x IEC 320 C19
Features
Cable length
How long the cable is.
3 m
Management features
Monitoring
Current, Power, Voltage
Power
AC input frequency
50 - 60 Hz
Nominal output voltage
The voltage which the manufacturer states that the device can produce.
230 V
Load capacity
7680 VA
Power
Maximum input current per phase
32 A
Maximum total current draw per phase
32 A
Maximum power
The maximum power that can be put into or produced by the device.
7680 W
Certificates
Certification
RoHS, REACH IEC 60950,VDE
Operational conditions
Operating temperature (T-T)
The minimum and maximum temperatures at which the product can be safely operated.
5 - 45 ?C
Storage temperature (T-T)
The minimum and maximum temperatures at which the product can be safely stored.
-25 - 65 ?C
Operating relative humidity (H-H)
5 - 95%
Storage relative humidity (H-H)
5 - 95%
Weight & dimensions
Width
The measurement or extent of something from side to side.
56 mm
Depth
The distance from the front to the back of something.
44 mm
Height
The measurement of the product from head to foot or from base to top.
91 mm
Weight
Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
6.93 kg
Logistics data
Total carbon footprint (kg of CO2e)
The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
28921.23
Additional Information
Shipping: |
Usually shipped within 3-5 working days |
Delivery: |
Usually delivered within 5-7 working days |