Apc
APC Smart-UPS SMT3000RMI2UC - 8x C13 1x C19 USB Rack Mountable SmartConnect 3000 SMT3000RMI2UC
- UPC:
- 0731304337348
- MPN:
- SMT3000RMI2UC
- Condition:
- New
- Availability:
- Available with FREE Delivery (usually delivered within 5-7 working days)
Description
Always stay online and prevent data loss
As soon as the power goes out, an APC Smart-UPS immediately provides emergency power to all connected equipment. Because an APC UPS does this automatically, you prevent unwanted failure of, for example, a PC, server or switch. With the free APC PowerChute software you can even have critical IT hardware shut down automatically and in a controlled manner when the battery of the UPS is almost empty. This way you prevent data loss, downtime and physical damage to hardware.
Safety
In addition, a Smart-UPS protects connected devices against peak voltage caused by lightning, among other things. This APC emergency power supply is ideally suited for (small) business use.
Battery life
You can easily read the expected battery life in the runtime graph, which you can find between the product images. You can easily see how long the UPS supplies emergency power at a certain load.
SmartConnect
Out-of-box remote UPS monitoring, free for a 6-month trial period. Using the SmartConnect ethernet port, you can easily connect the Smart-UPS to your network and easily monitor it remotely via the secure APC SmartConnect cloud-based web portal*. In addition, the UPS can always be monitored via this port via EcoStruxure IT Expert (SFTWES1-DIGI).
* Extend access to SmartConnect through the following licenses:1 year Standard Plan: ERWPMON1-1Y-DIGI
3 year Standard Plan: ERWPMON1-3Y-DIGI
1 year Advanced Plan: ERWPLUS1-1Y-DIGI
3 year Advanced Plan: ERWPLUS1-3Y-DIGI
PowerChute
By connecting the UPS to a maximum of one server via a USB cable, it can automatically provide it with a shutdown signal during a prolonged power outage and thus prevent a hard shutdown. This exact moment can be set via the free APC PowerChute Serial Edition software.
Network Management Card
If you connect the UPS directly to your network via the optional APC Network Management Card (AP9640/AP9641), it can easily be managed remotely via SNMP or our remote management software Ecostruxure IT Expert (SFTWES1-DIGI). You can also automatically send a shutdown signal via the network to multiple physical and/or virtual servers. By means of the APC PowerChute Network Shutdown Software associated with the network card can even be differentiated in the shutdown moment and the order in which this happens.
Ease of use
By means of physical buttons and an LCD screen make it possible to set and read the basic functionalities. Thanks to the included 4-post rail kit, you can easily mount the UPS in a rack.
Extend the lifespan
The internal battery cartridge (RBC43) can be replaced easily, safely and independently by the user. This without having to switch off the APC SMT3000RMI2UC or connected equipment. This way you can easily and cheaply extend the lifespan of the APC Smart-UPS and your equipment always remains online.
Warranty extension
The manufacturer's warranty of the SMT3000RMI2UC is 3 years, with the exception of the battery cartridge, which has a 2-year manufacturer's warranty. Both are extended by 3 years to 6 and 5 years respectively with the APC service pack (WBEXTWAR3YR-SP-04).
Switched Outlet Groups: Remote reboot and phased start-up
Thanks to the Switched Outlet Groups, it is possible to configure a phased/delayed power-on per UPS outlet group. This reduces the peak load on the UPS and brings it closer to the constant load, which limits oversizing of the UPS.
It is also possible to reset a group of multiple UPS outputs and the equipment connected to them. If SmartConnect Advanced (ERWPLUS1-1Y-DIGI) is used, a UPS with SmartConnect port + Ecostruxure IT Expert (SFTWES1-DIGI) or a network card (ap9640) in combination with Ecostruxure IT Expert (SFTWES1-DIGI), this is even possible at a distance.
Specs
Features
UPS topology
The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
Line-Interactive
Output power capacity
The maximum power that the device can produce.
3 kVA
Output power
The power that the device can produce.
2700 W
Waveform
Sine
Input operation voltage (min)
The minumum voltage needed by the device during operation.
1 V
Input operation voltage (max)
The maximum input voltage supported by the device.
302 V
Input frequency
The frequency (Hz) which is required to power the product.
50/60 Hz
Output operation voltage (min)
The minumum voltage produced by the device during operation.
220 V
Output operation voltage (max)
The maximum output voltage produced by the device.
240 V
Automatic Voltage Regulation (AVR)
Surge energy rating
A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
320 J
Hold time (min)
4 ms
Hold time (max)
8 ms
Efficiency
98.9%
Noise level
The amplitude level of the undesired background noise, usually measured in decibels (db).
55 dB
Audible alarm(s)
Alarms that make a sound when they are activated (set off).
Auto-restart
Ports & interfaces
AC outlet types
The type of outlet for AC electricity.
C13 coupler, C19 coupler
Power plug
A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
C20 coupler
AC outlets quantity
The number of sockets in the device where AC electrical power can be connected.
9 AC outlet(s)
Number of output IEC jumpers
3
USB port
The device features a socket into which a USB cable can be plugged.
Serial interface
Serial interface type
RJ-45
Ethernet LAN (RJ-45) ports
Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
1
SmartSlot
Battery
Battery technology
The type of battery in the device, e.g. nickel-cadmium (NiCd).
Sealed Lead Acid (VRLA)
Battery capacity
547 VAh
Typical backup time at full load
The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
3.2 min
Typical backup time at half load
The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
.5 min
Battery life (max)
5 year(s)
Battery recharge time
Approximate time required to recharge the battery from completely empty to completely full
3 h
Hot-swap battery
Automatic battery test
Cold start
Design
Form factor
The shape or design of the product.
Rackmount
Rack capacity
The spase that device fill in rack.
2U
Cable length
How long the cable is.
2 m
Product colour
The colour e.g. red, blue, green, black, white.
Black
Display type
Type of display (screen) e.g. LCD.
LCD
LED indicators
Status
Operational conditions
Operating temperature (T-T)
The minimum and maximum temperatures at which the product can be safely operated.
0 - 40 -C
Storage temperature (T-T)
The minimum and maximum temperatures at which the product can be safely stored.
-15 - 45 -C
Operating relative humidity (H-H)
0 - 95%
Storage relative humidity (H-H)
0 - 95%
Operating altitude
0 - 3000 m
Non-operating altitude
0 - 15000 m
Certificates
Compliance certificates
RoHS
Certification
CE, EAC, EN 60950, EN/IEC 62040-1, EN/IEC 62040-2, GS Mark, IRAM, RCM, VDE, WEEE, REACH, PEP, EOLI
Packaging content
Rack mount kit
Cables included
RS-232, USB cable
Quick installation guide
Sustainability
Sustainability certificates
Green Premium
Weight & dimensions
Width
The measurement or extent of something from side to side.
432 mm
Depth
The distance from the front to the back of something.
683 mm
Height
The measurement of the product from head to foot or from base to top.
86 mm
Weight
Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
44.3 kg
Packaging data
Software CD
Bundled software
Software distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.
Powershute Business Edition
Package width
The distance from one side of the packaging to the other.
600 mm
Package depth
The distance from the front to the back of the packaging.
980 mm
Package height
The distance from the top to the bottom of the packaging.
254 mm
Package weight
Weight of the packaged product.
51.7 kg
Logistics data
Harmonized System (HS) code
85078000
Total carbon footprint (kg of CO2e)
The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
2968.55
Other features
Nominal output voltage
The voltage which the manufacturer states that the device can produce.
230 V
Nominal input voltage
The voltage which the manufacturer recommends that the device needs to operate normally.
230 V
View AllClose
As soon as the power goes out, an APC Smart-UPS immediately provides emergency power to all connected equipment. Because an APC UPS does this automatically, you prevent unwanted failure of, for example, a PC, server or switch. With the free APC PowerChute software you can even have critical IT hardware shut down automatically and in a controlled manner when the battery of the UPS is almost empty. This way you prevent data loss, downtime and physical damage to hardware.
Safety
In addition, a Smart-UPS protects connected devices against peak voltage caused by lightning, among other things. This APC emergency power supply is ideally suited for (small) business use.
Battery life
You can easily read the expected battery life in the runtime graph, which you can find between the product images. You can easily see how long the UPS supplies emergency power at a certain load.
SmartConnect
Out-of-box remote UPS monitoring, free for a 6-month trial period. Using the SmartConnect ethernet port, you can easily connect the Smart-UPS to your network and easily monitor it remotely via the secure APC SmartConnect cloud-based web portal*. In addition, the UPS can always be monitored via this port via EcoStruxure IT Expert (SFTWES1-DIGI).
* Extend access to SmartConnect through the following licenses:1 year Standard Plan: ERWPMON1-1Y-DIGI
3 year Standard Plan: ERWPMON1-3Y-DIGI
1 year Advanced Plan: ERWPLUS1-1Y-DIGI
3 year Advanced Plan: ERWPLUS1-3Y-DIGI
PowerChute
By connecting the UPS to a maximum of one server via a USB cable, it can automatically provide it with a shutdown signal during a prolonged power outage and thus prevent a hard shutdown. This exact moment can be set via the free APC PowerChute Serial Edition software.
Network Management Card
If you connect the UPS directly to your network via the optional APC Network Management Card (AP9640/AP9641), it can easily be managed remotely via SNMP or our remote management software Ecostruxure IT Expert (SFTWES1-DIGI). You can also automatically send a shutdown signal via the network to multiple physical and/or virtual servers. By means of the APC PowerChute Network Shutdown Software associated with the network card can even be differentiated in the shutdown moment and the order in which this happens.
Ease of use
By means of physical buttons and an LCD screen make it possible to set and read the basic functionalities. Thanks to the included 4-post rail kit, you can easily mount the UPS in a rack.
Extend the lifespan
The internal battery cartridge (RBC43) can be replaced easily, safely and independently by the user. This without having to switch off the APC SMT3000RMI2UC or connected equipment. This way you can easily and cheaply extend the lifespan of the APC Smart-UPS and your equipment always remains online.
Warranty extension
The manufacturer's warranty of the SMT3000RMI2UC is 3 years, with the exception of the battery cartridge, which has a 2-year manufacturer's warranty. Both are extended by 3 years to 6 and 5 years respectively with the APC service pack (WBEXTWAR3YR-SP-04).
Switched Outlet Groups: Remote reboot and phased start-up
Thanks to the Switched Outlet Groups, it is possible to configure a phased/delayed power-on per UPS outlet group. This reduces the peak load on the UPS and brings it closer to the constant load, which limits oversizing of the UPS.
It is also possible to reset a group of multiple UPS outputs and the equipment connected to them. If SmartConnect Advanced (ERWPLUS1-1Y-DIGI) is used, a UPS with SmartConnect port + Ecostruxure IT Expert (SFTWES1-DIGI) or a network card (ap9640) in combination with Ecostruxure IT Expert (SFTWES1-DIGI), this is even possible at a distance.
Specs
Features
UPS topology
The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
Line-Interactive
Output power capacity
The maximum power that the device can produce.
3 kVA
Output power
The power that the device can produce.
2700 W
Waveform
Sine
Input operation voltage (min)
The minumum voltage needed by the device during operation.
1 V
Input operation voltage (max)
The maximum input voltage supported by the device.
302 V
Input frequency
The frequency (Hz) which is required to power the product.
50/60 Hz
Output operation voltage (min)
The minumum voltage produced by the device during operation.
220 V
Output operation voltage (max)
The maximum output voltage produced by the device.
240 V
Automatic Voltage Regulation (AVR)
Surge energy rating
A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
320 J
Hold time (min)
4 ms
Hold time (max)
8 ms
Efficiency
98.9%
Noise level
The amplitude level of the undesired background noise, usually measured in decibels (db).
55 dB
Audible alarm(s)
Alarms that make a sound when they are activated (set off).
Auto-restart
Ports & interfaces
AC outlet types
The type of outlet for AC electricity.
C13 coupler, C19 coupler
Power plug
A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
C20 coupler
AC outlets quantity
The number of sockets in the device where AC electrical power can be connected.
9 AC outlet(s)
Number of output IEC jumpers
3
USB port
The device features a socket into which a USB cable can be plugged.
Serial interface
Serial interface type
RJ-45
Ethernet LAN (RJ-45) ports
Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
1
SmartSlot
Battery
Battery technology
The type of battery in the device, e.g. nickel-cadmium (NiCd).
Sealed Lead Acid (VRLA)
Battery capacity
547 VAh
Typical backup time at full load
The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
3.2 min
Typical backup time at half load
The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
.5 min
Battery life (max)
5 year(s)
Battery recharge time
Approximate time required to recharge the battery from completely empty to completely full
3 h
Hot-swap battery
Automatic battery test
Cold start
Design
Form factor
The shape or design of the product.
Rackmount
Rack capacity
The spase that device fill in rack.
2U
Cable length
How long the cable is.
2 m
Product colour
The colour e.g. red, blue, green, black, white.
Black
Display type
Type of display (screen) e.g. LCD.
LCD
LED indicators
Status
Operational conditions
Operating temperature (T-T)
The minimum and maximum temperatures at which the product can be safely operated.
0 - 40 -C
Storage temperature (T-T)
The minimum and maximum temperatures at which the product can be safely stored.
-15 - 45 -C
Operating relative humidity (H-H)
0 - 95%
Storage relative humidity (H-H)
0 - 95%
Operating altitude
0 - 3000 m
Non-operating altitude
0 - 15000 m
Certificates
Compliance certificates
RoHS
Certification
CE, EAC, EN 60950, EN/IEC 62040-1, EN/IEC 62040-2, GS Mark, IRAM, RCM, VDE, WEEE, REACH, PEP, EOLI
Packaging content
Rack mount kit
Cables included
RS-232, USB cable
Quick installation guide
Sustainability
Sustainability certificates
Green Premium
Weight & dimensions
Width
The measurement or extent of something from side to side.
432 mm
Depth
The distance from the front to the back of something.
683 mm
Height
The measurement of the product from head to foot or from base to top.
86 mm
Weight
Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
44.3 kg
Packaging data
Software CD
Bundled software
Software distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.
Powershute Business Edition
Package width
The distance from one side of the packaging to the other.
600 mm
Package depth
The distance from the front to the back of the packaging.
980 mm
Package height
The distance from the top to the bottom of the packaging.
254 mm
Package weight
Weight of the packaged product.
51.7 kg
Logistics data
Harmonized System (HS) code
85078000
Total carbon footprint (kg of CO2e)
The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
2968.55
Other features
Nominal output voltage
The voltage which the manufacturer states that the device can produce.
230 V
Nominal input voltage
The voltage which the manufacturer recommends that the device needs to operate normally.
230 V
Additional Information
Shipping: |
Usually shipped within 3-5 working days |
Delivery: |
Usually delivered within 5-7 working days |