Apc
APC Smart-UPS uninterruptible power supply UPS Line-Interactive 0.45 kVA 280 W 4 SC450RMI1U
- UPC:
- 0731304222798
- MPN:
- SC450RMI1U
- Condition:
- New
- Availability:
- Available with FREE Delivery (usually delivered within 5-7 working days)
Description
This product is part of the Smart-UPS range, an intelligent and efficient network power protection offer from entry-level to scalable runtime. This 450VA/280W line-interactive UPS provides pure sine wave power to support critical electronics during power disruptions. The 1U rackmount SC features network grade protection, live swappable batteries, and built-in data line protection. It comes with IEC 320 C14 input, 4x IEC 320 C13 outlets and 2x IEC jumpers. The UPS has a 2-year warranty. Its dimensions are 383mm (depth) x 44mm (height) x 432mm (width) and weighs 10.18kg. Ideal for networking equipment and POS devices. It conforms to C-Tick, CE, EAC, GOST, TISI, and VDE. Designed for small and medium businesses looking to protect networking equipment and point-of-sale (POS) devices from power disturbances and outages.
Specs
Features
UPS topology
The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
Line-Interactive
Output power capacity
The maximum power that the device can produce.
0.45 kVA
Output power
The power that the device can produce.
280 W
Waveform
Sine
Input operation voltage (min)
The minumum voltage needed by the device during operation.
1 V
Input operation voltage (max)
The maximum input voltage supported by the device.
302 V
Input frequency
The frequency (Hz) which is required to power the product.
50/60 Hz
Automatic Voltage Regulation (AVR)
Surge energy rating
A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
320 J
Hold time (min)
4 ms
Hold time (max)
8 ms
Noise level
The amplitude level of the undesired background noise, usually measured in decibels (db).
38 dB
Surge protection
Surge protection features
Digital Subscriber Line (DSL), Fax, Modem, Network
Audible alarm(s)
Alarms that make a sound when they are activated (set off).
Audible alarm modes
Low battery alarm, Overload alarm
Auto-restart
Ports & interfaces
AC outlet types
The type of outlet for AC electricity.
C13 coupler
Power plug
A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
C14 coupler
AC outlets quantity
The number of sockets in the device where AC electrical power can be connected.
4 AC outlet(s)
Number of output IEC jumpers
2
Serial interface
Serial interface type
RS-232
Serial ports quantity
The number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial ports have largely been replaced by USBs and other interfaces.
1
Battery
Battery technology
The type of battery in the device, e.g. nickel–cadmium (NiCd).
Sealed Lead Acid (VRLA)
Battery capacity
8 VAh
Typical backup time at full load
The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
5.9 min
Typical backup time at half load
The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
.4 min
Battery life (max)
5 year(s)
Battery recharge time
Approximate time required to recharge the battery from completely empty to completely full
5 h
Hot-swap battery
Battery
Automatic battery test
Design
Form factor
The shape or design of the product.
Rackmount/Tower
Rack capacity
The spase that device fill in rack.
1U
Product colour
The colour e.g. red, blue, green, black, white.
Grey
LED indicators
Battery replacement
Operational conditions
Operating temperature (T-T)
The minimum and maximum temperatures at which the product can be safely operated.
0 - 40 °C
Storage temperature (T-T)
The minimum and maximum temperatures at which the product can be safely stored.
-15 - 45 °C
Operating relative humidity (H-H)
0 - 95%
Storage relative humidity (H-H)
0 - 95%
Operating altitude
0 - 3000 m
Non-operating altitude
0 - 15000 m
Certificates
Compliance certificates
RoHS
Certification
C-tick, CE, GOST, VDE, PEP, EOLI
Packaging content
Rack mount kit
Cables included
RS-232
Manual
Weight & dimensions
Width
The measurement or extent of something from side to side.
432 mm
Depth
The distance from the front to the back of something.
383 mm
Height
The measurement of the product from head to foot or from base to top.
44 mm
Weight
Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
.2 kg
Packaging data
Software CD
Package width
The distance from one side of the packaging to the other.
476 mm
Package depth
The distance from the front to the back of the packaging.
589 mm
Package height
The distance from the top to the bottom of the packaging.
4 mm
Package weight
Weight of the packaged product.
.7 kg
Logistics data
Products per pallet
Quantity of a single product per pallet. If more than one product is packed per carton; this is the number of products (not number of cartons) per shipping pallet.
24 pc(s)
Harmonized System (HS) code
85078000
Total carbon footprint (kg of CO2e)
The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
484.92
Other features
Nominal output voltage
The voltage which the manufacturer states that the device can produce.
230 V
View AllClose
Specs
Features
UPS topology
The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
Line-Interactive
Output power capacity
The maximum power that the device can produce.
0.45 kVA
Output power
The power that the device can produce.
280 W
Waveform
Sine
Input operation voltage (min)
The minumum voltage needed by the device during operation.
1 V
Input operation voltage (max)
The maximum input voltage supported by the device.
302 V
Input frequency
The frequency (Hz) which is required to power the product.
50/60 Hz
Automatic Voltage Regulation (AVR)
Surge energy rating
A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
320 J
Hold time (min)
4 ms
Hold time (max)
8 ms
Noise level
The amplitude level of the undesired background noise, usually measured in decibels (db).
38 dB
Surge protection
Surge protection features
Digital Subscriber Line (DSL), Fax, Modem, Network
Audible alarm(s)
Alarms that make a sound when they are activated (set off).
Audible alarm modes
Low battery alarm, Overload alarm
Auto-restart
Ports & interfaces
AC outlet types
The type of outlet for AC electricity.
C13 coupler
Power plug
A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
C14 coupler
AC outlets quantity
The number of sockets in the device where AC electrical power can be connected.
4 AC outlet(s)
Number of output IEC jumpers
2
Serial interface
Serial interface type
RS-232
Serial ports quantity
The number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial ports have largely been replaced by USBs and other interfaces.
1
Battery
Battery technology
The type of battery in the device, e.g. nickel–cadmium (NiCd).
Sealed Lead Acid (VRLA)
Battery capacity
8 VAh
Typical backup time at full load
The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
5.9 min
Typical backup time at half load
The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
.4 min
Battery life (max)
5 year(s)
Battery recharge time
Approximate time required to recharge the battery from completely empty to completely full
5 h
Hot-swap battery
Battery
Automatic battery test
Design
Form factor
The shape or design of the product.
Rackmount/Tower
Rack capacity
The spase that device fill in rack.
1U
Product colour
The colour e.g. red, blue, green, black, white.
Grey
LED indicators
Battery replacement
Operational conditions
Operating temperature (T-T)
The minimum and maximum temperatures at which the product can be safely operated.
0 - 40 °C
Storage temperature (T-T)
The minimum and maximum temperatures at which the product can be safely stored.
-15 - 45 °C
Operating relative humidity (H-H)
0 - 95%
Storage relative humidity (H-H)
0 - 95%
Operating altitude
0 - 3000 m
Non-operating altitude
0 - 15000 m
Certificates
Compliance certificates
RoHS
Certification
C-tick, CE, GOST, VDE, PEP, EOLI
Packaging content
Rack mount kit
Cables included
RS-232
Manual
Weight & dimensions
Width
The measurement or extent of something from side to side.
432 mm
Depth
The distance from the front to the back of something.
383 mm
Height
The measurement of the product from head to foot or from base to top.
44 mm
Weight
Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
.2 kg
Packaging data
Software CD
Package width
The distance from one side of the packaging to the other.
476 mm
Package depth
The distance from the front to the back of the packaging.
589 mm
Package height
The distance from the top to the bottom of the packaging.
4 mm
Package weight
Weight of the packaged product.
.7 kg
Logistics data
Products per pallet
Quantity of a single product per pallet. If more than one product is packed per carton; this is the number of products (not number of cartons) per shipping pallet.
24 pc(s)
Harmonized System (HS) code
85078000
Total carbon footprint (kg of CO2e)
The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
484.92
Other features
Nominal output voltage
The voltage which the manufacturer states that the device can produce.
230 V
Additional Information
Shipping: |
Usually shipped within 3-5 working days |
Delivery: |